Dry Type Transformer

Farady Electric manufacture a complete range of three phase distribution transformers, including oil-immersed type & cast resin dry-type transformer, we always designed with increased margins of safety and reliablity,and meet the following standard:IEC60076, IEEE Std, GB1094

Email your specs

Detail

General

Farady Electric manufacture a complete range of three phase distribution transformers, including oil-immersed type & cast resin dry-type transformer, we always designed with increased margins of safety and reliablity,and meet the following standard: IEC60076, IEEE Std, GB1094


Application

SC(B)10 series three phase resin-cast dry-type distribution transformer are in conformity with standard of IEC60076,with features of low loss, compact and light weight, low noise level,clamp-proof,anti-fouling,high mechanical strength, flame resisting, strong overload ability and low partial discharge quality,they are application to power transmission and distribution system,hotel,restaurant,commercial building,stadiums,chemical plants,stations,aiports,offshore drilling platforms,especially to heavy load centers and places with special fire protection requirements


Mainly Rating, Types & Capacity:

Three phase,

Two windings or three windings 

On-load or no-load voltage tapping changer 

Natural cooling or force air 

10-2500kVA


Service Condition

a) Suitable for indoor or outdoor application

b)Air temperature: 

Maximum temperature: +40℃; Minimum temperature:-30℃

c) Humidity: 

Monthly average humidity 95%; Daily average humidity 90% .

d) Altitude above sea level: 

Maximum installation altitude: 2000m.

e)Max wind speed:35M/s

f) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

g) No frequent violent shake

Note: * Beyond those services condition should enquiry to manufacturer technical dept during order


High Reliability Feature: 

● Flame resistant

● Explosion proof

● Low temperature rise

● Low loss & low noise

● No environmental contamination


Technical Specification(11kV Series)

1.jpg

Type

Voltage combination

Vector group

Loss(W)

 Impedance

%

Dimension

(L*W*H)
mm

Weight

(kg)

Primary

(KV)

Tapping range

Secondary

(KV)

No Load loss

Full
load loss

SC(B)10-30/10

 

6
6.3
6.6
10
10.5
11
13.2
13.8
15

±2x2.5%

0.4 or other

Yyn0 

or
Dyn11

190

700

4.0

680*400*686

300

SC(B)10-50/10

270

990

690*400*686

360

SC(B)10-80/10

360

1370

730*450*796

500

SC(B)10-100/10

400

1570

730*500*816

600

SC(B)10-125/10

470

1840

780*600*950

700

SC(B)10-160/10

540

2120

950*650*1124

850

SC(B)10-200/10

620

2520

990*650*1164

950

SC(B)10-250/10

720

2750

1020*650*1207

1100

SC(B)10-315/10

880

3460

1050*750*1320

1250

SC(B)10-400/10

970

3980

1100*800*1450

1550

SC(B)10-500/10

1160

4880

1140*800*1430

1850

SC(B)10-630/10

1340

5870

1250*800*1500

1900

SC(B)10-800/10

1520

6950

6.0

1330*800*1540

2200

SC(B)10-1000/10

1760

8120

1400*960*1640

2750

SC(B)10-1250/10

2090

9690

1450*960*1690

3300

SC(B)10-1600/10

2450

11730

1560*960*1930

4000

SC(B)10-2000/10

3320

14450

1680*960*1930

4800

SC(B)10-2500/10

3600

17170

1720*1010*1950

5500

Note: *The above parameter is only subject to our standard design, special requirement can be customized


Technical Specification(20kV Series)

2.jpg


Type

Voltage combination

Vector group

Loss(W)

 Impedance

%

 

Dimension
(L*W*H)
mm

 Weight

(kg)

 Primary

(KV)

 Tapping range

Secondary

(KV)

No Load loss

Full
load loss

SC(B)10-30/20

20

22
24

±2x2.5%

0.4 or other

Yyn0

or

Dyn11

220

800

6.0

980*480*750

435

SC(B)10-50/20

340

1240

1100*480*780

522

SC(B)10-80/20

410

1500

1160*500*800

725

SC(B)10-100/20

540

2000

1200*510*850

870

SC(B)10-125/20

580

2100

1200*600*900

1015

SC(B)10-160/20

680

2470

1220*650*1124

1233

SC(B)10-200/20

740

2950

1250*650*1164

1378

SC(B)10-250/20

800

3200

1280*670*1207

1595

SC(B)10-315/20

970

4090

1300*750*1400

1813

SC(B)10-400/20

1150

4850

1320*800*1450

2248

SC(B)10-500/20

1350

5800

1350*800*1490

2683

SC(B)10-630/20

1530

6840

1360*800*1530

2755

SC(B)10-800/20

1760

8270

1380*800*1580

3190

SC(B)10-1000/20

2070

9790

1430*960*1680

3988

SC(B)10-1250/20

2390

11540

1470*960*1720

4785

SC(B)10-1600/20

2790

13870

1560*960*1800

5800

SC(B)10-2000/20

3240

16390

1790*960*1930

6960

SC(B)10-2500/20

3870

19380

1800*1010*1950

7975

Note: *The above parameter is only subject to our standard design, special requirement can be customized


Technical Specification(35kV Series)

3.jpg

Type

Voltage combination

Vector group

Loss(W)

Impedance

%

 Dimension

(L*W*H)
mm

 Weight

(kg)

 Primary

(KV)

Tapping range

 Secondary

(KV)

No Load loss

Full
load loss

SC(B)10-30/35

33

34.5
35

±2x2.5%

0.4 or other

Yyn0

or
Dyn11

300

1350

6.5

1000*500*750

544

SC(B)10-50/35

380

1490

1180*530*780

653

SC(B)10-80/35

500

1950

1190*550*800

906

SC(B)10-100/35

640

2400

1220*560*850

1088

SC(B)10-125/35

750

2640

1240*600*900

1269

SC(B)10-160/35

820

3100

1260*670*1124

1541

SC(B)10-200/35

900

3700

1290*690*1164

1722

SC(B)10-250/35

1080

4350

1320*700*1207

1994

SC(B)10-315/35

1250

4400

1380*780*1400

2266

SC(B)10-400/35

1550

5660

1400*830*1450

2809

SC(B)10-500/35

1800

6970

1430*850*1490

3353

SC(B)10-630/35

2070

8120

1460*890*1530

3444

SC(B)10-800/35

2430

9630

1500*910*1580

3988

SC(B)10-1000/35

2700

11070

1520*960*1680

4984

SC(B)10-1250/35

3150

13400

1540*980*1720

5981

SC(B)10-1600/35

3600

16200

1590*1000*1800

7250

SC(B)10-2000/35

4230

19100

1830*1020*1930

8700

SC(B)10-2500/35

4950

22900

1900*1090*1950

9969

Note: *The above parameter is only subject to our standard design, special requirement can be customized